Skip to main content

Code_Aster Comparison

A two-storey steel and concrete building that uses every modelling feature, compared between AutoCalcs and a separate Code_Aster model for linear static, modal, P-Delta and buckling analyses.

It is the reference building from the model script guide: a braced steel frame with a haunched beam, semi-rigid connections, tension-only and scissor braces, a cracked roof slab with an opening, a retaining wall, a hinged canopy on tapered beams, a rigid floor, a support settlement and temperature loads. Both programs solve the same mesh, so the comparison checks how each feature is analysed rather than mesh refinement.

Two-storey test building with result contours: roof slab with an opening, retaining wall, canopy, braces and haunched beam

Model Definition

The same model was run in AutoCalcs and in Code_Aster (Euler-Bernoulli beams, flat shell elements, and the same offsets, releases, springs and ties). Each row is the governing value of that check over all load cases and combinations. A check passes when the two programs agree within 2%.

GeometryTwo storeys, 8 m (X) by 4 m (Z), floors at 4 m and 8 m, with a 2 m canopy off one end
Steel members200UC46, 310UB40, PFC 150, CHS 88.9x3.2 and IPE 200 from the library; E = 200 GPa
Member featuresHaunch and taper, semi-rigid ends, end releases, section turned 90°, offsets, tension-only braces, a scissor X-brace with a node link
Plates150 mm cracked roof slab with a stair opening, 200 mm retaining wall pinned along its base, 100 mm canopy hinged along the frame; concrete E = 30.1 GPa
SupportsFixed, pinned, a rotational spring base and a 10 mm settlement
FloorLevel 1 is a rigid diaphragm in its own plane
LoadsSelf-weight, floor pressure loads, slab and wall pressures, member loads, temperature (members and slab), wind and earth pressure
Results compared5 load cases and 7 combinations; P-Delta for 1.2G + 1.5E; buckling for 1.2G + 1.5Q; modal mass from G + 0.7Q

Plate result note: plate values are raw element results, not the smoothed contours the app shows by default. Results that depend on the in-plane stiffness of the slabs, such as slab membrane forces and the axial force a slab shares with the beam under it, are not compared: AutoCalcs uses enhanced in-plane shell formulations, while Code_Aster's linear shells use the basic ones, so on the same mesh they differ by element type rather than by analysis. Peaks at single nodes where a column meets a slab corner are also left out, as they change with the mesh in any program.

P-Delta and buckling note: AutoCalcs includes the in-plane geometric stiffness of walls and slabs, such as a loaded wall swaying in its own plane. The Code_Aster shells used for the building do not, so the building P-Delta and buckling checks below are brace and frame results, and the in-plane wall effect is checked on a separate wall strip against Code_Aster's COQUE_3D shell, which does include it. Twisting modes of open-section members are filtered from AutoCalcs buckling results and are not compared.

Code_Aster is open-source software from EDF. AutoCalcs is not affiliated with, certified by, or endorsed by EDF, and Code_Aster is not distributed as part of AutoCalcs.

Linear Static: Deformation

Largest node displacements over all load cases and combinations.

CheckAutoCalcsCode_AsterDifference
Max node displacement X, 1.2G + 1.5EEarth pressure on the end wall, propped by the level 1 floor.
16.48 mm16.47 mm0.10%
Max node displacement Y, 1.2G + 1.5QRoof slab, including the 10 mm support settlement at C0.
-16.38 mm-16.32 mm0.38%
Max node displacement Z, 1.2G + 1.5ERoof corner B2.
19.40 mm19.37 mm0.14%
Max node displacement X, temperature TRoof beams 20 °C warmer with a gradient through the depth; roof slab 15 °C warmer, top 10 °C warmer than soffit.
5.42 mm5.39 mm0.57%

Linear Static: Reactions

Support reactions, including the spring base, the settled support and the canopy post base.

CheckAutoCalcsCode_AsterDifference
Total vertical reaction, 1.2G + 1.5QEquals the applied load in every load case and combination in both programs.
664.79 kN664.79 kN<0.01%
Semi-rigid base B0 moment, 1.2G + 1.5ERotational spring of 5,000 kN-m/rad.
15.80 kN-m15.79 kN-m0.04%
Settled support C0 vertical reaction, 1.2G + 1.5Q10 mm predicted settlement, applied in every case and combination.
114.93 kN114.79 kN0.12%
Canopy post base F0 vertical reaction, 1.2G + 1.5E
40.28 kN40.47 kN0.48%

Linear Static: Members

Member end forces, one row per member feature.

CheckAutoCalcsCode_AsterDifference
Max column bending moment, 1.2G + 1.5EColumn CA1 at the fixed base A0.
84.60 kN-m84.61 kN-m<0.01%
Max column axial force, 1.2G + 1.5QColumn CB1 on the semi-rigid base.
175.92 kN175.99 kN0.04%
Haunched beam end moment, 1.2G + 1.5QL1AB, 300 mm haunch over 600 mm at both ends.
85.59 kN-m85.62 kN-m0.04%
Haunched beam torsion, 1.35GL1AB, from the point load with a torque at mid-span.
1.013 kN-m1.013 kN-m<0.01%
Semi-rigid end moment, 1.2G + 1.5QL1CD, end springs of 20,000 and 8,000 kN-m/rad and a minor-axis release.
53.34 kN-m53.36 kN-m0.04%
Tension-only brace axial force, 1.2G + 1.5EBR1. Both programs find the same braces active in all 12 results.
15.04 kN15.03 kN0.05%
Scissor X-brace axial force, 1.2G + 1.5EBZ3, diagonals joined at the crossing by a translation-only link.
46.40 kN46.37 kN0.07%
Girt end shear, wind WG1, section turned 90° and offset 180 mm from the column line.
6.000 kN6.000 kN<0.01%
Tapered canopy beam end moment, temperature TCN2, 300 mm deep at the frame tapering to the IPE 200, offset 100 mm below the canopy.
36.82 kN-m36.31 kN-m1.41%
Hinged beam shear, 1.35GL1BC, supporting the canopy slab along a hinged edge.
10.29 kN10.28 kN0.10%

Linear Static: Plates

Raw element bending moments and transverse shears in the wall and slabs.

CheckAutoCalcsCode_AsterDifference
Wall bending My, 1.2G + 1.5ERetaining wall under 0 to 40 kPa earth pressure, pinned along its base.
-72.51 kN-m/m-72.51 kN-m/m<0.01%
Wall transverse shear Qx, 1.2G + 1.5E
122.69 kN/m122.69 kN/m<0.01%
Canopy slab bending Mx, G + T
-4.97 kN-m/m-4.98 kN-m/m0.17%
Roof slab bending Mx, 1.2G + 1.5QCracked roof slab (stiffness factor 0.5) with a stair opening.
-15.43 kN-m/m-15.39 kN-m/m0.22%
Roof slab bending My, 1.2G + 1.5Q
-20.46 kN-m/m-20.20 kN-m/m1.27%

Modal Analysis

The first six AutoCalcs modes, with mass from G + 0.7Q, paired with Code_Aster by mode shape. Modes 1 (1.87 Hz) and 4 (2.20 Hz) are local sideways modes of the haunched floor beam, where Code_Aster finds one such mode (1.66 Hz, its mode 1). They are not compared: they depend on how a beam element represents the haunch.

CheckAutoCalcsCode_AsterDifference
Mode 2: sway in ZCode_Aster mode 2.
2.0573 Hz2.0627 Hz0.26%
Mode 3: sway in XCode_Aster mode 3.
2.1488 Hz2.1609 Hz0.56%
Mode 5: scissor X-brace, in planeCode_Aster mode 4.
2.9645 Hz2.9637 Hz0.03%
Mode 6: scissor X-brace, out of planeCode_Aster mode 5.
3.0040 Hz3.0039 Hz<0.01%

P-Delta Analysis

Second-order results for 1.2G + 1.5E.

CheckAutoCalcsCode_AsterDifference
Scissor-brace crossing, out-of-plane displacementFirst-order 2.72 mm; the compressed diagonal amplifies it about 3.6 times.
9.822 mm9.944 mm1.23%
Scissor X-brace axial force
46.92 kN46.75 kN0.35%
Max column bending moment
84.89 kN-m84.73 kN-m0.19%
Column axial force, CB1
104.07 kN104.29 kN0.21%

Buckling Analysis

Critical load factors for 1.2G + 1.5Q, paired by mode shape. The slender CHS scissor X-brace is the first member to buckle, so the first five AutoCalcs modes are all brace modes. Below them both programs find twisting modes of the open-section canopy and level 1 beams (Code_Aster modes 1 to 4 and 8, from 5.79). Without warping stiffness these twisting modes are not realistic, so AutoCalcs filters them from its results and they are not compared. Code_Aster mode numbers count positive load factors only.

CheckAutoCalcsCode_AsterDifference
Mode 1: scissor X-brace, out of planeCode_Aster mode 5.
7.7297.6411.14%
Mode 2: scissor X-brace, out of planeCode_Aster mode 6.
7.9987.9470.65%
Mode 3: scissor X-brace, out of planeCode_Aster mode 7.
8.0928.1300.47%
Mode 4: scissor X-brace, in planeCode_Aster mode 9.
9.3079.3300.25%
Mode 5: scissor X-brace, out of planeCode_Aster mode 10.
9.4639.5000.39%

In-Plane Wall: Buckling and P-Delta

A 0.5 m wide, 6 m tall, 100 mm thick wall strip modelled with shells, fixed at its base and held out of its plane, under 1,000 kN vertical and 10 kN horizontal load in its plane. Code_Aster uses its COQUE_3D shell on the same 4 by 24 element layout, as its other shells have no in-plane geometric stiffness.

CheckAutoCalcsCode_AsterDifference
In-plane buckling loadEuler cantilever π²EI / 4L² gives 2,141.8 kN; both shell models also include shear deformation.
2,133.7 kN2,131.5 kN0.11%
Top displacement with P-DeltaCode_Aster solved with large-displacement geometry. First-order 23.12 mm in AutoCalcs and 23.14 mm in Code_Aster; beam-column theory without shear deformation gives 42.94 mm.
43.22 mm43.31 mm0.21%