Skip to main content

IS 800:2007 Steel Design Calculator

Indian steel member checks to IS 800:2007 (limit state method, with Amendment No. 1): classification, tension, compression, bending, lateral-torsional buckling, shear, torsion and combined actions for one member.

Section Properties

Derived
A
5536.0mm²
Izz
84866458mm⁴
Iyy
5680608mm⁴
Zpz
641277mm³
Zpy
125390mm³
It
216652mm⁴
Iw
117266054677mm⁶
+y+z300 mm140 mm7.5 mm12.4 mm

Section & Material

fy = 250 MPa for t = 12.4 mm (below 20 mm), fu = 410 MPa

(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(m)
(m)
(m)
(m)

Load height acts through a load along the member: apply a Quick Calc loading, or a cantilever tip or uniform load, to choose it.

(kN·m)

Design Actions

(kN)
(kN·m)
(kN·m)
(kN)
(kN)
(kN·m)

Design Utilisation

Click "Run Check" to see design results

This calculator is a design aid only and is not a substitute for professional engineering judgement.

IS 800 Steel Member Design

Factored actions are checked against the IS 800:2007 design strengths with γm0 = 1.10 and γm1 = 1.25 (Table 5). Sections are classified to Table 2 for each action; the section and member checks below follow.

Clause Coverage:

  • Material and classification (Table 1 / Table 2 / 3.7.2): IS 2062 yield stress by the Table 1 thickness band of the thickest part, γm0 = 1.10 and γm1 = 1.25 (Table 5). Sections are classified per action to Table 2 as amended; slender sections use the 3.7.2(d) effective section (excess width deducted).
  • Tension (6.2 / 6.3.1 / 6.3.3): Gross section yielding and net section rupture 0.9 An fu / γm1 using the optional member net area; blank An checks yielding only. A single angle connected through one leg (end connection entered) ruptures with shear lag (6.3.3): the lesser of α An fu / γm1 with α = 0.6 and 0.9 Anc fu / γm1 + β Ago fy / γm0 with β = 0.7. It needs the net area An (Ag for a welded end); without it rupture is not checked and the angle shear lag row asks for An. Shear lag of other sections (6.3.4) and block shear (6.4) depend on the end detail and are not checked; check them separately.
  • Compression (7.1.2 / Table 10 / 7.5.1.2): Flexural buckling about both axes with the Table 10 curve (principal axes for angles). Single angles loaded through one leg use 7.5.1.2 when the end connection is entered. Channels and tees are also checked for torsional-flexural buckling, which IS 800 does not cover: elastic critical load from EN 1993-1-3 6.2.3 over the twist length KT L, then 7.1.2.1 with curve c; the smaller strength governs, also in 9.3.2.2.
  • Bending and LTB (8.2.1 / 8.2.2 / 8.3.1 / Annex E): Section bending with the 1.2 Ze fy / γm0 limit (1.5 for cantilevers). LTB uses Mcr from an elastic buckling analysis of the member (E-1.1), or the E-1.2 expression with Table 42 where that analysis cannot be used. Intermediate lateral restraints split the member into segments (8.3.1); partial restraints take 1.2 times the segment length with the E-1.2 expression. Restraints that hold only one flange are not covered: enter Mcr.
  • Shear (8.4 / 8.4.2.2(a) / 8.6.1.1 / 9.2.2): Shear yielding with the 8.4.1.1 shear area, shear buckling of webs with d/tw above 67ε by the simple post-critical method, minimum web thickness, and the high shear moment reduction of 9.2.2.
  • Torsion (8.4.1 basis): The entered torque is uniform along the member. IS 800:2007 has no member torsion clause. Closed hollow sections are checked for the Bredt shear flow against the shear yield stress fy/(√3 γm0) with a shear-torsion interaction; open sections (I, channel, tee, angle) are checked for the elastic shear stress from transverse shear plus St Venant torsion (T t/J) against the same stress. Warping torsion stresses (bimoment normal stress and warping shear) are not included; verify them separately where twist is restrained or the torque is large.
  • Combined actions (9.3.1 / 9.3.2.1 / 9.3.2.2 / Table 18): Section interaction to 9.3.1 (Table 17 exponents for plastic and compact I, RHS and CHS; linear otherwise), bending with tension to 9.3.2.1, and member buckling with bending to 9.3.2.2 using the Table 18 equivalent moment factors as amended. The buckling mode is set per axis: sway takes Cm = 0.9 (Table 18 note); unspecified takes the larger of 0.9 and the moment-diagram value with axial compression on a first-order analysis.

Supported Section Types

I-Sections - ISMB, ISLB, ISJB, ISWB, ISHB, ISNPB, ISWPB, ISPBP, ISSC
Channels - ISMC, ISLC, ISJC, ISPFC
Tees - ISNT, ISHT, ISMT, ISDT, ISLT
RHS / SHS - IS 4923
CHS - IS 1161
Angles - ISA equal and unequal

Current Limitations

  • One member with entered factored actions: no frame analysis. The entered actions are uniform along the member unless a Quick Calc loading gives the moment diagram.
  • Tension: blank An checks yielding of the gross section only; an angle connected through one leg needs An for rupture with shear lag (6.3.3). Block shear (6.4) is not checked.
  • Deflection (5.6.1, Table 6) needs service deflections from an analysis and is not checked here; use the 3D FEA design check.
  • Cold formed open sections (IS 801), built-up laced and battened members, the tension field method, stiffener design, web crippling and connections are outside these checks.
Benchmarks: 69 published comparisons, 0.06% average numerical difference
Full Documentation →

Other Design Code Calculators

Start Calculating Now

Model members and plates in 3D, then run automatic code checks on supported members.