Skip to main content

IS 800:2007

The IS 800 check verifies hot-rolled and welded steel members to IS 800:2007 General Construction in Steel, Code of Practice (limit state method) with Amendment No. 1 (2012), for I-sections, channels, tees, single angles, RHS/SHS and CHS. Units are metric. Sections come from the Indian section library or are entered by dimension.

Open IS 800:2007 Calculator · Verification report

Standard reference

StandardIS 800:2007 (third revision) with Amendment No. 1 (January 2012)
Design methodLimit state method with γm0 = 1.10 for yielding and buckling and γm1 = 1.25 for rupture (Table 5)
UnitsMetric (kN, kN·m, MPa, mm). Axes: z-z major, y-y minor (Fig. 2); u-u and v-v principal axes of angles
Verification69 published comparisons (worked examples and the design tables printed in the standard), 0.06% average numerical difference

Supported sections

  • I-sections: ISMB, ISLB, ISJB, ISWB, ISHB, ISNPB, ISWPB, ISPBP and ISSC; rolled or welded, including plate girders and unequal-flange I-sections.
  • Channels: ISMC, ISLC, ISJC and ISPFC.
  • Tees: ISNT, ISHT, ISMT, ISDT and ISLT, and tees from other section libraries.
  • Angles: ISA equal and unequal leg, single angles.
  • RHS/SHS: IS 4923, hot rolled, cold formed or welded box.
  • CHS: IS 1161, hot rolled or cold formed.

Cold-formed open sections are designed to IS 801 and are OUT OF SCOPE.

Checks performed

CheckClauseDescription
Section classification3.7, Table 2Plastic, compact, semi-compact or slender for each action; slender sections, including angle legs in bending, use the effective area and modulus of 3.7.2(d) (about inclined axes where the section is no longer symmetric).
Maximum slenderness3.8, Table 3WARNING where KL/r exceeds 180 in compression or L/r exceeds 400 in tension.
Tension6.2, 6.3.1Gross-section yielding; net-section rupture 0.9Anfu/γm1 for plates and other sections when a net area is entered.
Tension, angle connected through one leg6.3.3Rupture is the lower of the simplified method with α = 0.6 and the shear-lag method with β at its lower limit 0.7. Needs the net area; without it the row asks for additional verification.
Compression7.1.2.1, 7.3.2Aefy/γm0.
Flexural buckling, major and minor axis7.1.2, Tables 7 and 10Pd = Aefcd with the Table 10 buckling class; angles about their principal axes.
Torsional-flexural buckling, channels and tees (beyond IS 800)Beyond IS 800:2007: EN 1993-1-3 6.2.3, then 7.1.2.1 with curve cIS 800 gives flexural buckling only. Pd,TF = Aefcd from the elastic torsional-flexural load; it replaces Pdy in 9.3.2.2 where smaller.
Angle loaded through one leg7.5.1.2, Table 12Equivalent slenderness λe from k1, k2, k3 for the bolts and gusset fixity, curve c.
Bending, major and minor axis8.2.1.2, 8.2.1.1(a)Md = βbZpfy/γm0 ≤ 1.2Zefy/γm0 (1.5Ze for cantilevers); a web slender in bending leaves the moment to the flanges.
Lateral-torsional buckling8.2.2, 8.3.1, Annex EMd = βbZpfbd for I-sections, channels, tees and angles, per segment between intermediate lateral restraints.
Shear, major and minor axis8.4, 8.4.2.2(a)Avfyw/(√3 γm0); slender webs by the simple post-critical method.
Web thickness8.6.1.1d/tw ≤ 200εw unstiffened, and the transverse-stiffener limits.
Bending and shear9.2.2Reduced Mdv where V > 0.6Vd.
Bending and axial force9.3.1, Table 17Section interaction: 9.3.1.2 reduced moments for plastic and compact sections, linear form otherwise.
Bending and axial tension9.3.2.1Meff = M − ψTZec/A against the LTB strength.
Bending and axial compression9.3.2.2, Table 18Equations (a) and (b) with Ky, Kz, KLT and Cm from Table 18 as amended. Sway mode Unspecified checks both the sway (Cm = 0.9) and non-sway values on first-order actions with compression; the larger governs.
Second-order analysis4.4.2INCOMPLETE where Ky or Kz exceeds 1.4 with first-order moments.
Torsion; shear and torsion8.4.1 basisTorsional shear stress against fy/(√3 γm0); IS 800 has no member torsion clause.
Deflection, major and minor axis5.6.1, Table 6Beams: δ ≤ span/ratio on serviceability combinations.
Lateral deflection, major and minor axis5.6.1, Table 6Columns (FEA Design tab): δ relative to the base ≤ height/ratio on serviceability combinations.

Result states

StatusMeaningWhat to do
PASSEvery check performed is within its limit for the recorded inputs and assumptions. A combination in which every member force is zero passes and never governs over a loaded combination.Review any items under Additional verification required.
PASS (partial)The checks performed pass, but an applicable check could not be made.Complete the items listed under Additional verification required before relying on the result.
FAILDemand exceeds resistance, or a code limit is not met.Revise the member or the inputs.
INCOMPLETEA required input or a supported method is missing, so the check has no numerical resistance. The member reads INCOMPLETE when no check could be performed. It is not a PASS.Supply the missing input, or verify the check separately.
OUT OF SCOPEThe member, section or action is outside the scope of these checks. It is not a PASS.Design the member by other means.

Additional verification required lists the checks that apply to the member but are not performed here. The member status covers only the checks that were performed.

A utilisation above 0.90 is shown in amber but is still a PASS up to 1.00. A row marked WARNING is an advisory note on a condition to review; it never changes the member status.

Calculator inputs and sign conventions

Fabrication

I-sections: rolled or welded. RHS/SHS and CHS: cold formed or hot rolled. Channels, tees and angles: rolled. Fabrication sets the Fig. 2 widths, the Table 10 buckling class, the 8.4.1.1 shear area and αLT (0.21 rolled, 0.49 welded).

Section geometry

ShapeDimensions (mm)
I-sectionh, b, tw, tf. Optional b,bot, tf,bot for unequal flanges.
Channel, teeh, b, tw, tf
RHS/SHSh, b, t
CHSD, t
Angleh (leg 1), b (leg 2), t

Material

IS 2062 gradefy, t < 2020 ≤ t ≤ 40t > 40fu
E165165165165290
E250 (A, B, C)250240230410
E300300290280440
E350350330320490
E410410390380540
E450 D / E450 E450430420570 / 590

MPa, Table 1, with the band set by the thickest element of the section. IS 4923 and IS 1161 tubes are not Table 1 steels: enter fy and fu or pick a catalogue preset. Net area An (mm², optional) is used for 6.3.1 and 6.3.3 rupture; hole and stagger layouts are not inferred.

Member lengths and LTB

InputDescription
L, KLz, KLyMember length and flexural buckling lengths about z-z and y-y (7.2, Table 11). FEA Design tab: Kz and Ky × L.
LLTLTB effective length (8.3, Table 15); use the "normal load" value, as the load height is already in Mcr. L/n (KLT = 1/n) is read as n equal segments between intermediate lateral restraints (8.3.1).
Intermediate lateral restraints (8.3.1)Effective (default) or partial, for every intermediate restraint. Partial: each segment takes LLT = 1.2 × its length with the Annex E closed form.
McrOptional elastic critical moment (kN·m); replaces the calculated value.
Load heightShear centre, top flange or bottom flange, for Mcr.
Continuous restraintTop flange continuously restrained: sagging needs no LTB check; hogging is checked unrestrained over LLT.
CantileverAuto (FEA, from the supports), Span or Cantilever, with the held end. Sets the 1.5Ze limit, Cmy = Cmz = 0.9, CmLT = 1.0, Mcr with the held end built in and the Table 6 cantilever limit. Without a held end the cantilever deflection is INCOMPLETE.
Twist effective length factor KT (beyond IS 800)Channels and tees in compression: LT = KTL for torsional-flexural buckling, 0.5 to 5; default 1.0.
Web stiffener spacing cTransverse stiffener spacing (mm) for Kv (8.4.2.2(a)) and the 8.6.1.1 limits; blank means stiffeners at the supports only.
Single-angle end connectionConcentric, or one leg with 1 or 2+ bolts per end and fixed or hinged gusset (Table 12; also selects 6.3.3 in tension). For partial fixity choose hinged.

Combined actions and deflection

InputDescription
Sway buckling modePer axis: Unspecified (default: with compression on first-order actions, both Cm values checked), Sway (Cm = 0.9) or Non-sway (Table 18 from the moment diagram).
ψ (9.3.2.1)0.8 (default) where tension and moment can vary independently; 1.0 where they cannot.
Second-order momentsCalculator: tick only if the entered moments already include second-order effects (4.4.2).
Deflection limitTable 6 row, or an entered length/deflection ratio. Beams: the vertical rows (default: other buildings, elements not susceptible to cracking, span/300, cantilever span/150). Columns: the lateral rows (industrial without cranes, elastic cladding height/150 or brittle cladding height/240; crane columns, pendent operated height/200 or cab operated height/400; default: other buildings, inter storey drift, height/300).

Design actions

SymbolDescriptionUnitSign convention
PFactored axial forcekNPositive = compression
MzMajor-axis momentkN·mNegative = sagging (top flange, or tee flange, in compression); positive = hogging
MyMinor-axis momentkN·m-
VyShear paired with MzkN-
VzShear paired with MykN-
TTorque (uniform along the member in the standalone calculator)kN·m-

Assumptions you should know

  • Design uses E = 2.0 × 105 MPa and G = 0.769 × 105 MPa (2.2.4.1), whatever the analysis material stiffness.
  • The Table 2 web limit "42ε" (Amendment No. 1) is a lower bound on the general web limits.
  • Fig. 2 widths: rolled I outstand bf/2 and web D − 2(tf + r); welded I from the web face and D − 2tf; RHS B − 2t and D − 2t.
  • Table 2 gives only semi-compact limits for axial compression, so compression is classed as slender or not slender.
  • No moment is added for the shift of the effective centroid of a slender section; IS 800 gives none.
  • A channel with a slender flange in major-axis bending loses the tip of the compressed flange only, so its effective section bends about inclined axes. The bending and combined section checks use the least modulus of that unsymmetric bending, with both flanges taken as free to move sideways; lateral torsional buckling and 9.3.2 keep the z-z modulus.
  • The 1.2Ze limit of 8.2.1.2 applies to every member that is not a cantilever, including continuous members; it often governs tubes and minor-axis bending.
  • Mcr comes from an elastic buckling analysis of the member (E-1.1), with monosymmetry and the load height by its effect; otherwise E-1.2 with Table 42 (c1 = 1.0 where no case fits).
  • λLT is capped with Zec, the modulus to the compression fibre; fbd uses the 8.2.2 expression, not Table 13.
  • Segments between intermediate restraints each take their own moment diagram and Mcr; the governing segment feeds 9.3.2.2. The 8.3.2 destabilising factor is not applied.
  • 9.3.2.2 uses the maximum P, My and Mz along the member, even at different locations.
  • Table 18: the larger of the uniform-load and concentrated-load Cm; Cmy from the minor-axis diagram, Cmz and CmLT from the major-axis diagram.
  • 4.4.2: with a P-Delta analysis, LTB and 9.3.2.2 use the first-order member moments with the K factors; section checks use the full analysis moments.
  • 9.2.2: Mfd is Zp less the shear area; Mfd = 0 for minor-axis bending, CHS, tees and angles.
  • 9.3.1: channels, tees and angles use the linear form (no 9.3.1.2 expression).
  • Angles: principal axes, curve c; concentric loading (7.5.1.1) unless an end connection is set; shear area from the legs projected on the shear direction.
  • Unequal-angle LTB uses E-1.2 with Iw = 0 and the leg monosymmetry term, load at the shear centre.
  • Tees: the stem is classified only when its tip is in compression; LTB only where Iz > Iy, with Iw = 0.
  • Torsion: hollow sections by 2Amt, open sections by St Venant stress plus VQ/(It); warping stresses are not included.
  • Deflection of a beam is relative to the member ends (the held end of a cantilever), with the load factors of the combination as defined.
  • Deflection is checked on SLS combinations, on combinations with no limit state set, and on single load cases; never on ULS combinations. When the member has only ULS combinations and deflects, deflection is listed as not checked.
  • A member within about 32° of vertical is a column: its deflection is measured from its lower end, so it includes both the sway of the top and the bow between the ends. The whole-building drift rows of Table 6 are not member checks.

Not checked: verify separately

  • End connections: block shear (6.4), shear lag of sections other than single angles (6.3.4) and connection design (Section 10).
  • Plate girder details: web bearing and web buckling under concentrated loads, stiffener design (8.7) and the tension field method (8.4.2.2(b)).
  • Built-up members: laced and battened members (7.6, 7.7).
  • LTB where Mcr cannot be calculated (for example a cantilever with KLT other than 1.0, or an unequal angle loaded on a face): enter Mcr.
  • Slender CHS: IS 800 gives no effective section for tubes; OUT OF SCOPE.
  • Warping torsion: add warping stresses where twist is restrained or the torque is significant.
  • Other states: the 250 and 350 slenderness limits of Table 3 for wind or earthquake cases, lateral drift, vibration (5.6.2), fatigue, fire, working stress design (Section 11) and seismic detailing (Section 12).

Detailed derivations (formulas, substitutions and intermediate values) are in the handcalc report for each member.